EGM

3D Presentation Zoom
Lacquer spraying booths, chemical laboratories, chemical industry, petroleum chemistry, etc. The radial EGM fans are manufactured in compliance with the international standard ISO 9001 and the standard PN-EN 13980

Accessories

 

Application

For use in lacquer spraying booths, chemical laboratories, chemical industry, petroleum chemistry, etc. The radial EGM fans are manufactured in compliance with the international standard ISO 9001 and the standard PN-EN 13980.

 Designed for use in potentially explosive environments, other than coal mines and dog headings.

Equipment meets requirements set for the group II, category 2G/3G - zone 1 and/or 2 (Z1 and/or Z2) and 2D – zone 21 and/or 22 (Z21 and/or Z22) or category 2G/D. Awarded with a CE mark and meets requirements of the ATEX Directive 94/9/EC.

Construction

Rotors of the EGM fans are made of aluminum alloys or welded from steel sheet. They are self-cleaning and covered with powder paint.  All versions of EGM feature a rotor balanced according to ISO 1940-1.

Housing made of welded steel sheet, covered with powder paint (colour RAL 9005 – black). The housing is provided with inspection and drainage holes. To minimise the risk of sparking, some segments have been made of brazen sheet.

 On request, we can supply rotors and housing made of galvanised, zinc-coated or stainless steel.

Electric motor

The fans are provided with electric induction three-phase motors (230/400V or 400V, 50Hz) and are adapted for operation within potentially explosive environments. On request, we can supply motors with a different temperature rating and various housing protection e.g., types nA, d, de.

The EGM fans are designed for transporting media within the temperature range of -20°C to +60°C, provided that the temperature around the electric motor is within the range of -20°C - +40°C. Depending on the version of EGM fan, transported media may include: gas fumes, aerosols and dusts.  Standard configuration of the fans is LG270; other configurations are available on request. 

Selected models can be supplied in a version adapted for inverter control. Any non-standard and special orders require prior contact with Venture Industries Sp. z o.o.

NOTE

The user and fitter of the equipment are under obligation to comply with the rules and regulations specified in Directive 99/92/EC (“ATEX USERS”) (89/391/EWG) concerning minimum requirements in terms of improving the health and safety protection of workers potentially at risk from explosive environments. 

Vibration dampeners and a vibration monitering systems are mandatory for fans of 2D category (auxiliary accessories available at specialist suppliers). We recommend installation of protective mesh on the inlet and outlet of the fan, alongside vibration monitoring systems and vibration dampeners for all categories of this equipment.
Name Nominal
voltage [V]
Speed
[r.p.m.]
P max
[W]
I max
[A]
Q max
[m3/h]
P
static [Pa]
Weight
[kg]
Temp.
min.
[oC]
Temp.
max.
[oC]
EGM 80 II 2 G Ex c e IIB T3 400 2720 550 1.4 1030 1230 21 -20 60
EGM 100 II 2 G Ex c e IIB T3 400 2760 750 1.3 1000 1650 25 -20 60
EGM 130 II 2 G Ex c e IIB T3 400 2730 1100 2.4 1560 1890 27 -20 60
EGM 200 II 2 G Ex c e IIB T3 400 2850 1500 3.5 2200 1960 39 -20 60
EGM 300 II 2 G Ex c e IIB T3 400 2905 2400 4.8 1650 2480 58 -20 60
EGM 500 II 2 G Ex c e IIB T3 400 2915 5500 10.4 5850 2230 81 -20 60
EGM 700 II 2 G Ex c e IIB T3 400 2920 7000 12.7 5500 3170 118 -20 60
EGM 80 II 2 D Ex tD A21 IP 6X T 125oC 400 2800 550 1.36 1030 1230 21 -20 60
EGM 100 II 2 D Ex tD A21 IP 6X T 125oC 400 2855 750 1.75 1000 1650 25 -20 60
EGM 130 II 2 D Ex tD A21 IP 6X T 125oC 400 2845 1100 2.45 1560 1890 27 -20 60
EGM 200 II 2 D Ex tD A21 IP 6X T 125oC 400 2860 1500 3.3 2200 1960 39 -20 60
EGM 300 II 2 D Ex tD A21 IP 6X T 125oC 400 2890 3000 6.3 2500 2480 58 -20 60
EGM 500 II 2 D Ex tD A21 IP 6X T 125oC 400 2925 5500 10.5 5850 2230 81 -20 60
EGM 700 II 2 D Ex tD A21 IP 6X T 125oC 400 2930 7500 14.1 6650 3170 118 -20 60