JET FAN

3D Presentation Zoom

Designations

TJ 1 HT / 2 2- 3 630-6/41 - 4 15
 

  1. Insulation class
    F - General ventilation - insulation class F, motor guard IP55
    H - Smoke ventilator - insulation class H, motor guard IP55
  2. Number of motor poles (rotation speed)
    Single-speed motor - 2
    2/4 Two-speed motor - 2/4
  3. Model
  4. Power (kW)
Impulsion fan designed to move large volumes of air in car parks, tunnels and other large spaces.
 
Impulsion fan designed to move large volumes of air in car parks, tunnels and other large spaces.
JET FAN: “ventilation” models for air temerature within the range of -20°C to +40°C.
JET FAN: certified F400-120 (CE marked) in accordance with EN12101-3.

Range made of 5 diameters of tubular axial fans, from 400 mm to 630 mm.
Aluminium reversible blade.
External terminal box.

Hot galvanised steel casing supplied with two support feet.
Two circular sound atenuators made of galvanised sheet steel.
Supplied with a protection grille or deflector in order to guide the air.

Motors

Available, depending on the model, with:
JET FAN motors are IP55, Class F insulation TJHT motors are F400 120, IP55, Class H insulation.

Electrical supplies:
Name Pole Nominal
voltage [V]
Speed
[r.p.m.]
P max
[W]
I max
[A]
Q max
[m3/h]
Weight
[kg]
Temp.
min.
[oC]
Temp.
max.
[oC]
TJFT/2-315-6/41 400 2790 750 1.6 4500 57 -20 40
TJFT/2-355-6/41 400 2810 1100 2.3 6500 76 -20 40
TJFT/2-400-6/41 400 2870 1500 4.2 9000 89 -20 40
TJFT/2-450-6/41 400 2840 2200 4.5 12100 133 -20 40
TJFT/2-500-6/41 400 2890 4000 7.5 17500 165 -20 40
TJFT/2-560-6/41 400 2925 7500 13.6 25600 220 -20 40
TJFT/2-630-6/41 400 2945 15000 27 36100 290 -20 40
TJFU/2-315-6/41 400 2790 750 1.6 4600 56 -20 40
TJFU/2-355-6/41 400 2810 1100 2.3 6800 75 -20 40
TJFU/2-400-6/41 400 2870 1500 3 9700 88 -20 40
TJFT/2/4-315-6/41 HS 400 2820 850 1.9 4500 57 -20 40
TJFT/2/4-315-6/41 LS 400 1400 200 0.6 4500 57 -20 40
TJFT/2/4-355-6/41 HS 400 2810 1100 2.4 6500 76 -20 40
TJFT/2/4-355-6/41 LS 400 1390 250 0.75 6500 76 -20 40
TJFT/2/4-400-6/41 HS 400 2900 1500 4.2 9000 89 -20 40
TJFT/2/4-400-6/41 LS 400 1435 370 1.3 9000 89 -20 40
TJFT/2/4-450-6/41 HS 400 2845 2200 4.6 12100 134 -20 40
TJFT/2/4-450-6/41 LS 400 1420 500 1.5 12100 134 -20 40
TJFT/2/4-500-6/41 HS 400 2890 4400 8.6 17500 166 -20 40
TJFT/2/4-500-6/41 LS 400 1440 1100 2.8 17500 166 -20 40
TJFT/2/4-560-6/41 HS 400 2930 8000 15.3 25000 223 -20 40
TJFT/2/4-560-6/41 LS 400 1470 2000 4.8 25000 223 -20 40
TJFT/2/4-630-6/41 HS 400 2950 16000 30.5 36100 311 -20 40
TJFT/2/4-630-6/41 LS 400 1470 4000 9.6 36100 311 -20 40
TJFU/2/4-315-6/41 HS 400 2820 800 1.9 4600 56 -20 40
TJFU/2/4-315-6/41 LS 400 1400 200 0.6 4600 56 -20 40
TJFU/2/4-355-6/41 HS 400 2810 1100 2.4 6800 75 -20 40
TJFU/2/4-355-6/41 LS 400 1390 250 0.75 6800 75 -20 40
TJFU/2/4-400-6/41 HS 400 2900 1500 3.5 9700 88 -20 40
TJFU/2/4-400-6/41 LS 400 1435 370 1.3 9700 88 -20 40
TJHT/2-315-6/41 400 2790 750 1.6 4500 57 -20 40
TJHT/2-355-6/41 400 2810 1100 2.3 6500 76 -20 40
TJHT/2-400-6/41 400 2870 1500 4.2 9000 89 -20 40
TJHT/2-450-6/41 400 2840 2200 4.5 12100 133 -20 40
TJHT/2-500-6/41 400 2890 4000 7.5 17500 165 -20 40
TJHT/2-560-6/41 400 2925 7500 13.6 25000 220 -20 40
TJHT/2-630-6/41 400 2945 15000 27 36100 290 -20 40
TJHU/2-315-6/41 400 2790 750 1.6 4600 56 -20 40
TJHU/2-355-6/41 400 2810 1100 2.3 6800 75 -20 40
TJHU/2-400-6/41 400 2870 1500 3 9700 88 -20 40
TJHT/2/4-315-6/41 HS 400 2820 800 1.91 4500 57 -20 40
TJHT/2/4-315-6/41 LS 400 1400 200 0.6 4500 57 -20 40
TJHT/2/4-355-6/41 HS 400 2810 1100 2.41 6500 76 -20 40
TJHT/2/4-355-6/41 LS 400 1390 250 0.75 6500 76 -20 40
TJHT/2/4-400-6/41 HS 400 2900 1500 3.5 9000 89 -20 40
TJHT/2/4-400-6/41 LS 400 1435 370 1.3 9000 89 -20 40
TJHT/2/4-450-6/41 HS 400 2845 2200 4.6 12100 134 -20 40
TJHT/2/4-450-6/41 LS 400 1420 500 1.5 12100 134 -20 40
TJHT/2/4-500-6/41 HS 400 2890 4400 8.6 17500 166 -20 40
TJHT/2/4-500-6/41 LS 400 1440 1100 2.8 17500 166 -20 40
TJHT/2/4-560-6/41 HS 400 2930 8000 15.3 25000 223 -20 40
TJHT/2/4-560-6/41 LS 400 1470 2000 4.8 25000 223 -20 40
TJHT/2/4-630-6/41 HS 400 2950 16000 30.5 36100 311 -20 40
TJHT/2/4-630-6/41 LS 400 1470 4000 9.6 36100 311 -20 40
TJHU/2/4-315-6/41 HS 400 2820 800 1.9 4600 56 -20 40
TJHU/2/4-315-6/41 LS 400 1400 200 0.6 4600 56 -20 40
TJHU/2/4-355-6/41 HS 400 2810 1100 2.4 6800 75 -20 40
TJHU/2/4-355-6/41 LS 400 1390 250 0.75 6800 75 -20 40
TJHU/2/4-400-6/41 HS 400 2900 1500 3.5 9700 88 -20 40
TJHU/2/4-400-6/41 LS 400 1435 370 1.3 9700 88 -20 40